Valvular & structural heart diseaseCohort study

1-Year Outcomes of transcatheter aortic valve replacement (TAVR) With ACURATE neo2 vs SAPIEN/Evolut

JACC Cardiovasc IntervPublished

  • Registry-based target trial emulation
  • nationwide
  • balancing weighting adjustment
  • Median follow-up 352 days (Q1-Q3: 193.5-365 days)

ACURATE neo2: predilatation 100%, postdilatation 45% (n = 288)

Authors' conclusion

There was no difference in clinical outcomes at 1 year between the ACURATE neo2 and the Evolut or SAPIEN valves.

Study context

Population
Patients undergoing TAVR in Sweden (SWEDEHEART registry), IDE trial inclusion and exclusion criteria
Participants
644 vs 1,299
Exposure
TAVR with ACURATE neo2 vs SAPIEN or Evolut
  • ACURATE neo2n = 644
  • Controln = 1,299reference
Outcome
Mortality, stroke and HF hospitalization combined
Follow-up
1 year

Main finding

As reported in the abstract

12 months

Adjusted hazard ratio

0.97

95% CI 0.75–1.23

ACURATE neo2 vs Control
adjusted HR 0.97 (95% CI 0.75–1.23)

Observational data: associations, not effects.

Further findings

Individual components, MI, percutaneous intervention · 12 months

No difference between ACURATE neo2 and control

Postdilatation within ACURATE neo2

Postdilatation not significantly associated with adverse outcomes

Safety

Major bleeding · 12 months

No difference between ACURATE neo2 and control

Original publication

1-Year Outcomes of TAVR With ACURATE neo2 vs SAPIEN/Evolut. JACC Cardiovasc Interv. Published 24 November 2025. doi:10.1016/j.jcin.2025.09.025

Summarised from the published abstract; every number is checked against it