Heart failure & cardiomyopathiesDiagnostic or prognostic study

124 I-Evuzamitide Positron Emission Tomography/Computed Tomography for Diagnosing Cardiac Amyloidosis

JAMAPublished

  • Diagnostic accuracy study
  • prospective
  • multicentre (18 US centres)
  • single-group
  • blinded image review
  • blinded adjudication

Authors' conclusion

124I-evuzamitide PET/CT is highly sensitive and specific for diagnosing cardiac amyloidosis with an acceptable safety profile.

Study context

Population
Adults with suspected cardiac amyloidosis presenting for diagnostic evaluation, without established cardiac or systemic amyloidosis170 included
Participants
195 adults
Outcome
Sensitivity and specificity of 124I-evuzamitide for the diagnosis of cardiac amyloidosis (coprimary)

Performance

As reported in the abstract

Diagnosis of cardiac amyloidosis (coprimary: sensitivity and specificity)

Overall sensitivity

94% (95% CI, 85%-98%; P < .001)

Overall specificity

86% (95% CI, 77%-92%; P < .001)

Further findings

PPV and NPV for cardiac amyloidosis

PPV
85% (95% CI, 75%-92%)
NPV
94% (95% CI, 87%-98%)

Original publication

124 I-Evuzamitide Positron Emission Tomography/Computed Tomography for Diagnosing Cardiac Amyloidosis. JAMA. Published 30 August 2026. doi:10.1001/jama.2026.17361