Heart failure & cardiomyopathies

124Iodine Evuzamitide Positron Emission Tomography in Patients With Established or Suspected Cardiac Amyloidosis

JACC Cardiovasc ImagingPublished Diagnostic accuracy study

Authors' conclusion

124I-evuzamitide PET provides excellent diagnostic accuracy in patients known or suspected to have CA and might provide a single upstream assessment for the presence or absence of CA.

Study context

Population
Consecutive patients with known or suspected cardiac amyloidosis (CA)Positron emission tomography (PET)/MRI 123, PET/CT 3
Participants
126 patients
Comparison
124I-evuzamitide PET in patients with vs without CA
  • CAn = 87
Outcome
Diagnostic performance and safety of 124I-evuzamitide PET/MRI (positive scan: LV myocardial uptake > blood pool, visual read by 3 experts)
Methodological detailsopen-label, prospective, consecutive patients
  • Open-label
  • Prospective
  • Consecutive patients

Performance

As reported in the abstract

Visual scan read for CA
Test or modelSensitivitySpecificity
CA100%Not reported in the abstract
No CANot reported in the abstract100%

Sensitivity

CA100%
No CANot reported in the abstract

Specificity

CANot reported in the abstract
No CA100%
Inter-reader agreement (Fleiss's kappa); disagreement on 5 patients, none with CA
0.94

Further findings

Mean

OutcomeCANo CAP value
LV/blood pool standardized uptake value ratio1.89 (SD 0.29)0.91 (SD 0.15)P < 0.001

Safety

Tracer-related adverse events

Well tolerated, without significant tracer-related adverse events

Original publication

124Iodine Evuzamitide Positron Emission Tomography in Patients With Established or Suspected Cardiac Amyloidosis. JACC Cardiovasc Imaging. Published 30 August 2026. doi:10.1016/j.jcmg.2026.08.005

Summarised from the published abstract; every number is checked against it