Valvular & structural heart diseaseDiagnostic or prognostic study

3-Dimensional Echocardiographic Prediction of Left Ventricular Outflow Tract Area Prior to Transcatheter Mitral Valve Replacement

JACC Cardiovasc ImagingPublished

  • Retrospective diagnostic accuracy study
  • consecutive patients
  • 2 tertiary care centres

Authors' conclusion

TEE-derived analysis provides comparable results with CT-derived metrics in predicting the neo-LVOT area and peak gradient after TMVR.

Study context

Population
Patients undergoing transcatheter mitral valve replacement (TMVR) at 2 tertiary care centres, October 2017 to May 2023
Participants
105 consecutive patients
Comparison
3D transesophageal echocardiography (TEE) vs baseline computed tomography (CT) for neo-left ventricular outflow tract (neo-LVOT) and mitral annular measurement
Outcome
Accuracy of 3D echocardiographic analysis vs baseline CT

Performance

As reported in the abstract

Baseline neo-LVOT prediction, TEE vs CT
  • No significant bias in baseline neo-LVOT prediction between both imaging modalities
  • TEE significantly underestimated mitral annular (MA) area, perimeter and medial-lateral dimension vs CT

Further findings

Predicted vs actual (postprocedural) neo-LVOT area

P TEE P < 0.001 · CT P = 0.046

OutcomeTEECT
Correlation of predicted neo-LVOT area with postprocedural peak LVOT gradient (inverse)
r20.4810.401
PP < 0.001P < 0.001

Predicted vs actual (postprocedural) neo-LVOT area

Both modalities significantly underestimated the actual neo-LVOT area, driven by underestimation with dedicated mitral valve bioprosthesis

Original publication

3-Dimensional Echocardiographic Prediction of Left Ventricular Outflow Tract Area Prior to Transcatheter Mitral Valve Replacement. JACC Cardiovasc Imaging. Published 24 July 2024. doi:10.1016/j.jcmg.2024.05.011

Summarised from the published abstract; every number is checked against it