Coronary disease & ACS

5-Year Outcomes After Bioresorbable Coronary Scaffolds Implanted With Improved Technique

J Am Coll CardiolPublished Randomised controlled trial

Authors' conclusion

In this large-scale, blinded randomized trial, despite the improved implantation technique, the absolute 5-year rate of target lesion failure was 3% greater after BVS compared with CoCr-EES.

Study context

Population
Patients with stable or acute coronary syndromes
Participants
2,604 patients
Comparison
Bioresorbable vascular scaffolds (BVS) with improved technique vs CoCr-EES
Primary endpoint
Target lesion failure
Follow-up
5 years
Methodological detailsblinded, multicentre (147 sites), Patients, clinical assessors and event adjudicators blinded; 5-year follow-up completed
  • Blinded
  • Multicentre (147 sites)
  • Patients, clinical assessors and event adjudicators blinded; 5-year follow-up completed

Primary result

As reported in the abstract

P = 0.03

Further findings

Recurrent angina (centrally adjudicated) · within 5 years · cumulative rate

P = 0.63

Event rates over time

Slightly greater with BVS than CoCr-EES through 3 years; similar between 3 and 5 years

Safety

Device thrombosis · within 5 years

P = 0.15

Parts of this Brief are withheld: the automatic checks could not confirm them against the abstract.

Original publication

5-Year Outcomes After Bioresorbable Coronary Scaffolds Implanted With Improved Technique. J Am Coll Cardiol. Published 17 May 2023. doi:10.1016/j.jacc.2023.05.003

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.