A streamlined pathway for transcatheter aortic valve implantation: the BENCHMARK study

Eur Heart JPublished

  • Before-and-after study
  • multicentre
  • 28 sites in 7 European countries

Authors' conclusion

Broad implementation of BENCHMARK practices contributes to improving efficiency of TAVI pathway reducing LoS and costs without compromising patient safety.

Study context

Population
Patients with severe symptomatic aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI) with balloon-expandable valves, 2020–2023
Participants
1,491 vs 897
Comparison
After vs before implementation of BENCHMARK best practices
  • Aftern = 1,491
  • Beforen = 897reference
Outcome
Hospital length of stay (LoS) and duration of intensive care stay

Main finding

As reported in the abstract

Hospital LoS and duration of intensive care stay

Mean length of stay (LoS), before vs after BENCHMARK implementation (days)

7.7 ± 7.0 vs 5.8 ± 5.6

Median LoS, before vs after (days)

6 vs. 4; P < .001

Duration of intensive care, before vs after (days)

1.8 vs 1.3

Median intensive care duration, before vs after (days)

1.1 vs. 0.9; P < .001

Secondary outcomes

Use of local anaesthesia

Increased use of local anaesthesia after vs before implementation
96.1% vs. 84.3%; P < .001

Procedure and intervention times

Median procedure time, after vs before (min)
47 vs. 60; P < .001
Intervention time, after vs before (min)
85 vs. 95; P < .001

Safety

30-day safety (both groups combined)

No differences between groups; all-cause mortality
0.6%
Stroke/TIA
1.4%
Life-threatening bleeding
1.3%
Stage 2/3 AKI
0.7%
Valve-related readmission
1.2%
  • rates for both groups combined

Original publication

A streamlined pathway for transcatheter aortic valve implantation: the BENCHMARK study. Eur Heart J. Published 30 March 2024. doi:10.1093/eurheartj/ehae147

Summarised from the published abstract; every number is checked against it