Coronary disease & ACSRandomised controlled trial

Accelerated Diagnostic Pathways for Suspected Acute Coronary Syndrome in Practice

J Am Coll CardiolPublished

  • Randomised controlled trial
  • pragmatic
  • noninferiority
  • implementation trial

Authors' conclusion

Implementation of the ESC 0/1-hour pathway failed to discharge significantly more patients within 4 hours of presentation compared with the 0/3-hour ADP. In addition, The ESC 0/1-hour was noninferior to the 0/3-hour hs-cTn pathway for safety of discharge, although safety for both pathways was less than that imputed by observational studies.

Study context

Population
Patients with suspected acute coronary syndrome (ACS) at 2 major EDs in North-West England, December 2021 to July 202413,983 screened
Participants
3,543 patients
Comparison
European Society of Cardiology (ESC) 0/1-hour vs 0/3-hour hs-cTn accelerated diagnostic pathway
Primary endpoint
Efficiency: proportion discharged within 4 hours; safety: MACE (adjudicated index or representation type 1 myocardial infarction (MI), CV death, urgent coronary revascularization) in those discharged as not ACS
Follow-up
Within 30 days

Primary result

As reported in the abstract

Proportion discharged within 4 hours

Proportion discharged within 4 h relatively low and did not differ substantially (21.8% vs 19.2%)

P = 0.07

Safety

Outcome0/1-hour0/3-hourabsolute difference in sensitivity (1-sided 97.5% CI)
Sensitivity for 30-day MACE in discharged patients · within 30 days · noninferior93.7% (95% CI 88.4%–97.1%)89.5% (95% CI 82.7%–94.3%)+4.2% (−2.5)
  • Sensitivity for 30-day major adverse cardiac events (MACE) in discharged patients: noninferiority margin 3%
  • Sensitivity for 30-day MACE in discharged patients: 1-sided 97.5% CI

Original publication

Accelerated Diagnostic Pathways for Suspected Acute Coronary Syndrome in Practice. J Am Coll Cardiol. Published 20 May 2026. doi:10.1016/j.jacc.2026.02.5135

Summarised from the published abstract; every number is checked against it