Arrhythmias & electrophysiologyCohort study

Adverse outcomes due to atrioventricular synchrony loss induced by temporary VVI pacing in patients with pre-existing DDD stimulation: insights from a device recall scenario

EuropacePublished

  • Prospective observational study
  • natural experiment (device recall)
  • Ventricular pacing >88% throughout
  • Clinical events tracked for 12 months

Authors' conclusion

Temporary loss of AV synchrony in chronically DDD-paced patients was associated with rapid, severe, and only partially reversible clinical and echocardiographic deterioration.

Study context

Population
Patients in sinus rhythm chronically adapted to DDD stimulation with recalled DDD pacemakers (79.9 ± 16.0 years; 63.4% atrioventricular (AV) block)
Participants
93 patients
Exposure
Temporary VVI/VVIR pacing vs subsequent DDD restoration
Outcome
Changes in LVEF and heart failure (HF) hospitalizations

Main finding

As reported in the abstract

HF hospitalizations

P < 0.001

OutcomeVVI/VVIRDDDP value
LVEF (from 57.3% baseline)53.0%Not reported in the abstract
LVEF after restorationNot reported in the abstract54.8%
Left ventricular ejection fraction (LVEF) decline from 57.3% to 53.0% during VVI/VVIR
P < 0.001
After DDD restoration LVEF 54.8%, still significantly worse than baseline
P < 0.05

Observational data: associations, not effects.

Secondary outcomes

BNP

BNP increase from 155 to 260 pg/mL during VVI/VVIR
P < 0.001
BNP decreased to 210 pg/mL after DDD restoration, still significantly worse than baseline
P < 0.05

Original publication

Adverse outcomes due to atrioventricular synchrony loss induced by temporary VVI pacing in patients with pre-existing DDD stimulation: insights from a device recall scenario. Europace. Published 7 April 2026. doi:10.1093/europace/euag068

Summarised from the published abstract; every number is checked against it