Valvular & structural heart diseaseCohort study

Association of incomplete device apposition with stroke recurrence after patent foramen ovale closure

HeartPublished

  • prospective cohort study
  • four centres in China (2020-2026)

Authors' conclusion

IDA is common after PFO closure and is associated with increased risks of recurrent stroke and new-onset symptoms. Preventive strategies warrant further investigation.

Study context

Population
Patients without known vascular risk factors who underwent transcatheter patent foramen ovale (PFO) closure for secondary prevention with follow-up ≥6 monthsincluded from 382 consecutive candidates
Participants
233 patients
Exposure
Patients with incomplete device apposition (IDA) vs without IDA

Main finding

As reported in the abstract

Recurrent stroke · median follow-up of 20.00 (IQR 18.00-24.00) months
  • IDA: P = 0.022

Observational data: associations, not effects.

Further findings

OutcomeP value
New-onset symptoms (atrial tachyarrhythmia, migraine headache, chest pain/discomfort) · median follow-up of 20.00 (IQR 18.00-24.00) months · higher risk with IDAP < 0.001

Prevalence and location of IDA · 6 months post closure

IDA observed
55.8%
Predominantly at the anterior-inferior rim
93.4%

Factors associated with IDA

IDA significantly associated with larger and longer PFOs, larger devices and greater in vivo device thickness
P < 0.001 for all

Device apposition on repeat CT angiography (CTA)

In eight patients who underwent repeat CTA, device apposition remained stable after 6-month closure

Pathological validation

Available in one patient with severe chest pain/discomfort; a well-apposed device had sufficient endothelialisation

Original publication

Association of incomplete device apposition with stroke recurrence after patent foramen ovale closure. Heart. Published 7 August 2026. doi:10.1136/heartjnl-2026-327956