Arrhythmias & electrophysiologyCase-control study

Atrial fibrillation in embolic stroke of undetermined source: role of advanced imaging of left atrial function

Eur J Prev CardiolPublished

  • Retrospective case-control study
  • single-centre
  • risk prediction model
  • internal validation by bootstrapping

Authors' conclusion

The novel PADS score can identify the risk of AF on prolonged monitoring with ILR following ESUS and should be considered a dedicated risk stratification tool for decision-making regarding the screening strategy for AF in stroke.

Study context

Population
Patients with embolic stroke of undetermined source (ESUS) referred for implantable loop recorder (ILR) implantation, December 2009 to September 2019293 stroke, 30 TIA
Participants
323 patients
Outcome
AF detection on ILR monitoring; risk prediction model for AF (PADS score)
Follow-up
Mean 710 days

Main finding

As reported in the abstract

PADS score for AF identification
Atrial fibrillation (AF) of any duration detected
47.1%
Lateral PA (increasing), OR
1.011
Age (increasing), OR
1.035
Diastolic BP (higher), OR
1.027
Left atrial (LA) reservoir strain (abnormal), OR
0.973
Model discrimination, AUC
0.72
Bootstrap internal validation (1000 samples of 150 patients), AUC
0.73

Observational data: associations, not effects.

Original publication

Atrial fibrillation in embolic stroke of undetermined source: role of advanced imaging of left atrial function. Eur J Prev Cardiol. Published 11 July 2023. doi:10.1093/eurjpc/zwad228

Summarised from the published abstract; every number is checked against it