Valvular & structural heart diseaseDiagnostic or prognostic study

Automated Deep Learning Phenotyping of Tricuspid Regurgitation in Echocardiography

JAMA CardiolPublished

  • Diagnostic accuracy study
  • temporally distinct test set
  • geographically distinct external cohort

Authors' conclusion

In this study, an automated pipeline was developed to identify clinically significant TR with excellent performance.

Study context

Population
Color Doppler echocardiogram studies; development at Cedars-Sinai Medical Center (CSMC) 2011–2021 (47,312 studies, 31,708 patients), chosen for parity across tricuspid regurgitation (TR) severity classestest studies per cohort
Participants
2,462 vs 5,549
Comparison
CSMC test vs Stanford Healthcare (SHC)
  • CSMC testn = 2,462
  • SHCn = 5,549
Outcome
AUC, sensitivity and specificity for identifying A4C videos with color Doppler across the tricuspid valve, and AUC for identifying moderate to severe or severe TR

Performance

As reported in the abstract

Test or modelView classifier AUCStudies with ≥1 A4C color Doppler video identifiedView classifier sensitivityView classifier specificityModerate or severe TR AUCSevere TR AUCStudies with ≥1 TR color Doppler video identified
CSMC test1.000 (95% CI, 0.999-1.000)2410 of 24620.975 (95% CI, 0.968-0.982)1.000 (95% CI, 1.000-1.000)0.928 (95% CI, 0.913-0.943)0.956 (95% CI, 0.940-0.969)
SHC0.999 (95% CI, 0.998-0.999)0.949 (95% CI, 0.944-0.955)0.999 (95% CI, 0.999-0.999)0.951 (95% CI, 0.938-0.962)0.980 (95% CI, 0.966-0.988)5268 of the 5549

Original publication

Automated Deep Learning Phenotyping of Tricuspid Regurgitation in Echocardiography. JAMA Cardiol. Published 1 June 2025. doi:10.1001/jamacardio.2025.0498

Summarised from the published abstract; every number is checked against it