Congenital heart diseaseCohort study

Biventricular Pressure-Volume Area Ratio for the Assessment of Left Ventricular Preparedness for Double Switch Operation

JACC AdvPublished

  • Retrospective cohort
  • conductance catheter validation
  • univariate Cox proportional hazards

Authors' conclusion

Estimation of subpulmonary LV-PVA using simple imaging and catheterization data was reliable compared to gold standards. LV:RV ePVA ratio ≥0.67 may serve as a good discriminator for LV preparedness for DSO for congenitally corrected transposition of the great arteries/intact ventricular septum.

Study context

Population
Patients with congenitally corrected transposition of the great arteries/intact ventricular septum undergoing double switch operation (DSO)retrospective cohort, validation of ePVA against measured pressure-volume area (PVA) in n = 20 · validation (measured PVA) 20 · retrospective cohort 42
Participants
42 patients
Exposure
Left ventricular (LV):Right ventricular (RV) ePVA ratio and clinical variables vs composite outcome (≥moderate LV dysfunction, transplant, or death); ePVA vs measured PVA

Main finding

As reported in the abstract

Agreement of ePVA with measured PVA
  • High agreement and low bias with measured PVA
  • n = 20

Observational data: associations, not effects.

Further findings

Associations with composite outcome

ComparisonHR (95% CI)
Low LV:RV ePVA ratio · univariate Cox proportional hazards3.9 (1.5–10.0)
Low pressure ratio · univariate Cox proportional hazards2.4 (1.3–4.2)

Composite outcome (≥moderate LV dysfunction, transplant, or death) · median follow-up 1.65 [0.12, 4.58] years

Patients with composite outcome
6/42 patients (14%)
Median age at DSO
2.9 years

Associations with composite outcome

LV mass indices not significantly associated

Adverse outcome among patients with borderline pressure ratios (subgroup)

Of 8 patients with borderline pressure ratios, those with ePVA ratio <0.67 who had adverse outcome
5
Of 8 patients with borderline pressure ratios, those with ePVA ratio ≥0.67, none with adverse outcome
3

Original publication

Biventricular Pressure-Volume Area Ratio for the Assessment of Left Ventricular Preparedness for Double Switch Operation. JACC Adv. Published 24 February 2026. doi:10.1016/j.jacadv.2026.102616

Summarised from the published abstract; every number is checked against it