Cardio-oncology & otherCohort study

Cardiac implantable electronic device trends and infection risk in cardiac sarcoidosis: A 30-year perspective from southern and western Sweden

Heart RhythmPublished

  • retrospective cohort study
  • 2 Swedish tertiary centers

Authors' conclusion

In CS, early recognition and ICD utilization, particularly for primary prevention, have increased. CIED infection rates were similar regardless of the timing of immunosuppression initiation relative to CIED implantation.

Study context

Population
Patients with cardiac sarcoidosis who received a CIED, 1994–2023received a CIED, of 212 patients diagnosed with cardiac sarcoidosis (CS)
Participants
140 patients
Exposure
Device type and indications before and after the 2014 Heart Rhythm Society consensus (1994-2014 vs 2015-2023); CIED infection rates according to immunosuppression initiation (>10 days after implantation vs within or before 10 days)

Main finding

As reported in the abstract

ICD as first implanted device
Implantable cardioverter-defibrillator (ICDs) first implanted device, overall
70.7%
for primary prevention
59.7%

Observational data: associations, not effects.

Further findings

Outcomemean interval (years)P value
Mean interval from CS diagnosis to CIED implantation · significantly shortened after 2014−1.5 vs 0.1 yearsP = 0.037

Safety

Outcome1994-20142015-2023delayed immunosuppressionearly-initiated immunosuppression
CIED infection · 1 yearNot reported in the abstractNot reported in the abstract7.5%5%
CIED infection — overall CIED infection rate
6.4% (n = 9)

Original publication

Cardiac implantable electronic device trends and infection risk in cardiac sarcoidosis: A 30-year perspective from southern and western Sweden. Heart Rhythm. Published 6 August 2026. doi:10.1016/j.hrthm.2026.07.014

Summarised from the published abstract; every number is checked against it