Heart failure & cardiomyopathies

Characterization and Application of Novel Exercise Recovery Patterns That Reflect Cardiac Performance: A Substudy of the SEQUOIA-HCM Trial

CirculationPublished Secondary analysis of the SEQUOIA-HCM randomised trial, with a derivation referral cohort

Primary resultResult — go to the resultHazard ratio 1.54 95% CI 1.35–1.76

Authors' conclusion

This study established VO2T12.5% as a new measure that reflects cardiac performance during exercise and predicted heart failure event-free survival. Furthermore, VO2T12.5% improved proportional to improvements in left ventricular outflow tract gradient and cardiac biomarkers in response to aficamten treatment, a cardiospecific therapy for obstructive hypertrophic cardiomyopathy.

Study context

Population
Referral cohort with dyspnea on exertion undergoing CPET with hemodynamic monitoring (MGH-ExS); participants with symptomatic obstructive hypertrophic cardiomyopathy (SEQUOIA-HCM)814 MGH-ExS
Comparison
Aficamten vs placebo; VO2T12.5% ≥35 vs <35 seconds
Primary endpoint
HF hospitalization or death (MGH-ExS)
Methodological detailsMGH-ExS, phase 3, substudy
  • MGH-ExS
  • Phase 3
  • Substudy

Primary result

As reported in the abstract

Hazard ratio

1.54

95% CI 1.35–1.76

P < 0.001

Per 15-second increase in VO2T12.5%
HR 1.54 (95% CI 1.35–1.76); P < 0.001

Per 15-second increase in VO2T12.5%, as printed

Further findings

OutcomeOR (95% CI)
Improvement of VO2T12.5% by ≥15 seconds (SEQUOIA-HCM) · 24 weeksNNT=4.83.7 (1.9–6.9)
OutcomeDifference (seconds) (95% CI)P value
Change in VO2T12.5% (SEQUOIA-HCM) · 24 weeksImproved; baseline VO2T12.5% 45±20 seconds8 (−12 to −5)P < 0.001
  • Change in VO2T12.5% (SEQUOIA-HCM): 263 participants with CPET at baseline and week 24

Exercise PCWP to cardiac output slope and peripheral oxygen extraction, VO2T12.5% ≥35 vs <35 seconds (MGH-ExS)

Elevated exercise pulmonary capillary wedge pressure to cardiac output slope with longer VO2T12.5%
P < 0.0001
No difference in peripheral oxygen extraction
P = 0.11

Correlation of VO2T12.5% shortening with NT-proBNP, hs-cTnI and LV outflow tract gradient

Shortening of VO2T12.5% correlated with reduced NT-proBNP, high-sensitivity cardiac troponin I and LV outflow tract gradient
all P<0.005

Original publication

Characterization and Application of Novel Exercise Recovery Patterns That Reflect Cardiac Performance: A Substudy of the SEQUOIA-HCM Trial. Circulation. Published 5 September 2025. doi:10.1161/circulationaha.124.073585

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.