Arrhythmias & electrophysiologyRandomised controlled trial

Chlorhexidine vs Povidone-Iodine Alcohol Solutions for Cardiac Implantable Electronic Devices

J Am Coll CardiolPublished

  • Randomised controlled trial
  • multicentre
  • open-label
  • blinded outcome adjudication

Authors' conclusion

The study did not demonstrate a significant reduction in infection rates with alcoholic chlorhexidine compared with alcoholic povidone-iodine in patients undergoing cardiac resynchronization device implantation. Both antiseptics showed similar rates of major infectious and noninfectious events.

Study context

Population
Patients undergoing cardiac resynchronization therapy (CRT) (implantation, upgrade or replacement) pacemaker or defibrillator implantation
Participants
2,272 patients
Comparison
2% alcoholic chlorhexidine vs alcoholic povidone-iodine skin antisepsis
  • Chlorhexidinen = 1,143
  • Povidone-iodinen = 1,129reference
Primary endpoint
Local or systemic device-related infection
Follow-up
24-month follow-up

Primary result

Device-related infection · 24 months

Adjusted subhazard ratio

0.75

95% CI 0.48–1.20

P = 0.23

By group

As reported in the abstract

Secondary outcomes

Major CV events

subhazard ratio 1.01 (0.87–1.17)

Safety

Noninfectious local side effects

Noninfectious local side effects
12.9% vs 13.3%

Original publication

Chlorhexidine vs Povidone-Iodine Alcohol Solutions for Cardiac Implantable Electronic Devices. J Am Coll Cardiol. Published 20 January 2026. doi:10.1016/j.jacc.2025.10.042

Summarised from the published abstract; every number is checked against it