Arrhythmias & electrophysiologyCohort study

Clinical Effectiveness of Transcatheter Left Atrial Appendage Occlusion With Watchman FLX Compared With First-Generation Watchman

JACC Cardiovasc IntervPublished

  • Registry-based cohort study
  • National Cardiovascular Data Registry Left Atrial Appendage Occlusion (LAAO) Registry
  • secondary analysis with 2:1 propensity score matching

Authors' conclusion

Transcatheter LAAO with the Watchman FLX is associated with significantly lower risks for major adverse events and ischemic stroke at 1 year compared with the predicate Watchman device.

Study context

Population
Patients undergoing transcatheter LAAO in the National Cardiovascular Data Registry LAAO Registry
Exposure
Watchman FLX vs Watchman 2.5
Outcome
Ischemic stroke
Follow-up
1 year

Main finding

As reported in the abstract

Adjusted hazard ratio

0.82

95% CI 0.68–0.98

P = 0.02

Watchman FLX vs Watchman 2.5
adjusted HR 0.82 (95% CI 0.68–0.98); P = 0.02

Observational data: associations, not effects.

Further findings

Outcomeadjusted HR (95% CI)P value
Major adverse events · 1 year0.84 (0.80–0.88)P < 0.0001
Ischemic stroke or systemic embolism · 1 year0.74 (0.62–0.87)P = 0.0003

Any peridevice leak (TEE at 45 days)

P < 0.001

Safety

Device-related thrombus (TEE at 45 days)

P = 0.27

Original publication

Clinical Effectiveness of Transcatheter Left Atrial Appendage Occlusion With Watchman FLX Compared With First-Generation Watchman. JACC Cardiovasc Interv. Published 26 May 2025. doi:10.1016/j.jcin.2025.03.025

Summarised from the published abstract; every number is checked against it