Valvular & structural heart diseaseCohort study

Clinical Outcomes of Redo Transcatheter Aortic Valve Replacement According to Computed Tomography Sizing

JACC Cardiovasc IntervPublished

  • Retrospective cohort study
  • Median follow-up 368 days (Q1-Q3: 96-611 days)

Authors' conclusion

In patients undergoing redo-TAVR with preprocedural CT planning, a sizing strategy enabling selective TAV-2 oversizing relative to the LZ was associated with favorable outcomes without increased procedural complications.

Study context

Population
Consecutive patients undergoing redo-TAVR with preprocedural computed tomographic (CT) planning
Participants
150 patients
Exposure
Landing zone (LZ)-concordant vs LZ-discordant TAV-2 sizing in redo-TAVR

Main finding

As reported in the abstract

Bioprosthetic valve failure · 1 year

Estimated rate of bioprosthetic valve failure, overall

8.7% (95% CI: 3.1%-14.2%)

Observational data: associations, not effects.

Further findings

OutcomeHR (95% CI)P value
Independent predictors of bioprosthetic valve failure — LZ perimeter <62 mm vs LZ concordant4.19 (1.37–12.8)P = 0.012
Independent predictors of bioprosthetic valve failure — TAV-2 size smaller than manufacturer sizing range for aortic annulus vs LZ concordant3.75 (1.25–11.2)P = 0.018

Transcatheter aortic valve (TAV-1) compression

TAV-1 compression
97.3%

LZ-discordant TAV-2 sizes

Patients receiving LZ-discordant TAV-2 sizes
52%
Oversizing to the LZ
21.2% (15.8%-24.8%)
Oversizing to the annulus
7.1% (3.1%-10.9%)
  • mostly larger than recommended TAV-2

Device success · 30 days

Device success
73.3%

Safety

Annular rupture

Annular rupture events
0

Original publication

Clinical Outcomes of Redo Transcatheter Aortic Valve Replacement According to Computed Tomography Sizing. JACC Cardiovasc Interv. Published 27 October 2025. doi:10.1016/j.jcin.2025.08.034

Summarised from the published abstract; every number is checked against it