Arrhythmias & electrophysiology
Conduction System Pacing in Pediatric Patients: Outcomes From a Multicenter International Cohort
Authors' conclusion
CSP is a feasible, safe, and durable physiological pacing strategy in children, with excellent long-term CSP preservation and stable electrical performance despite ongoing somatic growth. CSP may also provide effective physiological resynchronization in pediatric patients requiring CRT.
Study context
- Population
- Patients aged ≤18 years undergoing His bundle pacing or left bundle branch area pacing
- Participants
- 120 patients
- Outcome
- Long-term preservation of CSP
- Follow-up
- Median 24 months (Q1-Q3: 10-54 months)
Methodological detailsconsecutive patients, 9 experienced centers
- Consecutive patients
- 9 experienced centers
Main finding
As reported in the abstract
Conduction system pacing (CSP) preserved, among 101 patients with CSP at implantation and follow-up capture assessment
95
94.1%
Kaplan-Meier-estimated freedom from loss of CSP at 1 year
100.0%
Kaplan-Meier-estimated freedom from loss of CSP at 2 and 3 years
98.2%
95% CI 94.7%–100.0%
Observational data: associations, not effects.
Further findings
Baseline indications
- Congenital atrioventricular block
- 68 (56.7%)
- Congenital heart disease
- 41 (34.2%)
- CSP for heart failure/CRT
- 12 (10.0%)
Acute CSP implantation success
- Successful
- 116 patients (96.7%)
Electrical lead performance
- Remained stable
Left ventricular ejection fraction, CRT subgroup
- Improved from 28.8% ± 9.4% to 46.8% ± 12.0%
- P < 0.001
Safety
- CSP lead-related complications
- 10 patients (8.3%)
- Reintervention required
- 9 (7.5%)
Original publication