Arrhythmias & electrophysiologyCohort study

Contemporary catheter ablation of complex atrial tachycardias after prior atrial fibrillation ablation: pulsed field vs. radiofrequency current energy ablation guided by high-density mapping

EuropacePublished

  • Prospective matched cohort study
  • consecutive patients
  • high-density mapping

Authors' conclusion

Pulsed field ablation of post-ablation LAT using a pentaspline catheter is feasible, safe, and faster but less effective compared to standard RFC ablation after one year of follow-up.

Study context

Population
Patients undergoing catheter ablation of LAT after prior AF ablation, 09/2021–02/202377 AT (67 LAT)
Participants
56 patients
Exposure
Pulsed field ablation (PFA) vs radiofrequency current (RFC) ablation for post-ablation LAT
  • PFAn = 28
  • RFCn = 28reference

Main finding

Arrhythmia-free survival (estimated) · 1 year

Hazard ratio

2.91

95% CI 1.11–7.65

P = 0.0473

By group

PFA vs RFC
HR 2.91 (95% CI 1.11–7.65); P = 0.0473

As reported in the abstract

Observational data: associations, not effects.

Further findings

Acute LAT termination during ablation

P = 1.0

Procedure time

P < 0.0001

Fluoroscopy time

P = 0.04

Safety

Major complications

No major complications

Original publication

Contemporary catheter ablation of complex atrial tachycardias after prior atrial fibrillation ablation: pulsed field vs. radiofrequency current energy ablation guided by high-density mapping. Europace. Published 21 March 2024. doi:10.1093/europace/euae072

Summarised from the published abstract; every number is checked against it