Secondary analysis

Coronary artery restenosis treatment with plain balloon, drug-coated balloon, or drug-eluting stent: 10-year outcomes of the ISAR-DESIRE 3 trial

Eur Heart JPublished

  • Secondary analysis of the ISAR-DESIRE 3 randomised trial
  • 10-year extended follow-up
  • events independently adjudicated

Authors' conclusion

Ten years after PCI for DES-ISR, the primary and major secondary endpoints between PCB and PES were not significantly different.

Study context

Population
Patients with drug-eluting stent (DES) in-stent restenosis undergoing percutaneous coronary intervention (PCI)
Participants
402 patients · 500 lesions
Comparison
Plain balloon (PB) vs paclitaxel-coated balloon (PCB) vs paclitaxel-eluting stent (PES)
  • PBn = 134reference
  • PCBn = 137
  • PESn = 131
Primary endpoint
Composite of:
  • Cardiac death
  • Target vessel MI
  • Target lesion thrombosis
  • Target lesion revascularization
Follow-up
10 years

Primary result

As reported in the abstract

PCB vs PESHazard ratio (95% CI)P value
weighted Cox; multiplicity-adjusted P
1.10(0.80–1.51)
P = 0.610
Cox
1.10(0.79–1.52)
Royston-Parmar
1.08(0.72–1.60)

Secondary outcomes

OutcomePBPCBPESHR (95% CI)P value
Target lesion revascularization (major secondary efficacy endpoint) · 10 years · weighted Cox; multiplicity-adjusted P58.0%43.9%38.6%0.83 (0.56–1.22)P = 0.282
Target lesion revascularization (major secondary efficacy endpoint) · 10 years · Cox0.81 (0.54–1.21)
Target lesion revascularization (major secondary efficacy endpoint) · 10 years · Royston-Parmar0.75 (0.47–1.20)
  • Target lesion revascularization (major secondary efficacy endpoint): overall P < 0.0001
  • Target lesion revascularization (major secondary efficacy endpoint): Grambsch-Therneau P = 0.002

Landmark analyses: death and cardiac death · within 5 years

Excess of death and cardiac death with PES vs PCB within 5 years; 10-year differences not significant after multiplicity adjustment

Competing risk analysis

No significant difference in TLR between PCB and PES; increased risk of death with PES vs PCB

Lesion-level and per-protocol analyses

Consistent

Safety

Major secondary safety endpoint (cardiac death, target vessel MI or target lesion thrombosis) · 10 years

  • Major secondary safety endpoint (cardiac death, target vessel MI or target lesion thrombosis): P = 0.564

Original publication

Coronary artery restenosis treatment with plain balloon, drug-coated balloon, or drug-eluting stent: 10-year outcomes of the ISAR-DESIRE 3 trial. Eur Heart J. Published 21 February 2023. doi:10.1093/eurheartj/ehad026

Summarised from the published abstract; every number is checked against it