Coronary disease & ACSDiagnostic or prognostic study

Coronary Artery Stenosis Evaluation by Angiography-Derived Fractional Flow Reserve (FFR)

JACC Cardiovasc ImagingPublished

  • Diagnostic accuracy study
  • prospective
  • observational

Authors' conclusion

With 82Rb-PET as reference modality, the wire-free QFR solution showed similar diagnostic accuracy as invasive FFR in evaluation of intermediate coronary stenosis.

Study context

Population
Symptomatic patients with suspected obstructive CAD on coronary CT angiography (≥50% diameter stenosis in ≥1 vessel), intermediate (30%-90%) stenoses
Participants
250 patients · 320 vessels
Comparison
QFR vs invasive FFR, with 82Rb-PET MPI as reference standard
Outcome
Ability to identify reduced myocardial blood flow (<2 mL/g/min) during vasodilation and/or relative perfusion abnormalities (summed stress score ≥4 in ≥2 adjacent segments) on 82Rb-PET

Performance

As reported in the abstract

Diagnostic accuracy vs 82Rb-PET
Test or modelPer-patient accuracyPer-vessel accuracy
QFR73% (95% CI: 67%-79%)70% (95% CI: 64%-75%)
FFR71% (95% CI: 64%-78%)68% (95% CI: 62%-73%)

Further findings

OutcomeQFRFFR
82Rb-PET stress myocardial blood flow per 0.10 increase in index+0.08 (95% CI 0.02–0.14) mL/g/min+0.14 (95% CI 0.07–0.21) mL/g/min
Per-vessel feasibility · intention-to-diagnose analysis84% (95% CI 80%–88%)88% (95% CI 85%–92%)

Original publication

Coronary Artery Stenosis Evaluation by Angiography-Derived FFR. JACC Cardiovasc Imaging. Published 12 April 2023. doi:10.1016/j.jcmg.2023.02.008

Summarised from the published abstract; every number is checked against it