Heart failure & cardiomyopathiesDiagnostic or prognostic study

CT Coronary Angiography and Dynamic CT Myocardial Perfusion for Detection of Cardiac Allograft Vasculopathy

JACC Cardiovasc ImagingPublished

  • Diagnostic accuracy study

Authors' conclusion

The combination of CT-MPI and CCTA demonstrated excellent diagnostic performance for the detection of CAV.

Study context

Population
Heart transplantation patients (median 4.3 years after transplantation)35 (55.6%) with cardiac allograft vasculopathy (CAV)
Participants
63 patients
Comparison
Computed tomography-myocardial perfusion imaging (CT-MPI) and coronary computed tomography angiography (CCTA) vs invasive coronary angiography (ICA) with intravascular ultrasonography (IVUS) for CAV
Outcome
Diagnostic performance of dynamic CT-MPI and CCTA for CAV

Performance

As reported in the abstract

Detection of CAV
Test or modelAUCSensitivitySpecificityPPVNPV
CCTA stenosis + MBFmin0.88674.3%96.4%96.3%75.0%

Further findings

OutcomeValuesP value
MBFglobal, CAV vs no CAVCAV median 128.7 mL/100 mL/min · No CAV median 150.4 mL/100 mL/minP = 0.014
MBFmin, CAV vs no CAVCAV median 96.9 mL/100 mL/min · No CAV median 122.8 mL/100 mL/minP < 0.001

Original publication

CT Coronary Angiography and Dynamic CT Myocardial Perfusion for Detection of Cardiac Allograft Vasculopathy. JACC Cardiovasc Imaging. Published 12 April 2023. doi:10.1016/j.jcmg.2022.12.031

Summarised from the published abstract; every number is checked against it