Arrhythmias & electrophysiology
Deep Learning With Longitudinal Electrocardiograms Predicts Atrial Fibrillation Better Than a Single Electrocardiogram
Authors' conclusion
A longitudinal deep learning model using serial 12-lead ECGs improved 1-year AF prediction over a matched single-ECG model. Longitudinal ECG modeling may provide a scalable approach to identify patients warranting enhanced AF surveillance.
Study context
- Population
- Patients with 12-lead Electrocardiogram (ECGs) at Weill Cornell Medicine/NewYork-Presbyterian and in MIMIC-IV-ECGcohorts · 107,811 (institutional) · 55,307 (MIMIC-IV-ECG)
- Predictors
- Transformer-based model that accepts variable-length sequences of prior 12-lead ECGs with time-aware encoding of irregular intervals (longitudinal model), compared with a single-ECG model
- Predicted outcome
- AF documented more than 1 and within 365 days after an index ECG
Methodological detailsmodels developed at Weill Cornell Medicine/NewYork-Presbyterian, evaluated on MIMIC-IV-ECG without and with fine-tuning, patient-cluster bootstrapping with 1 random index ECG per patient
- Models developed at Weill Cornell Medicine/NewYork-Presbyterian
- Evaluated on MIMIC-IV-ECG without and with fine-tuning
- Patient-cluster bootstrapping with 1 random index ECG per patient
Model performance
As reported in the abstract
Paired area under the receiver-operating characteristic curve, fine-tuned longitudinal model with age and sex vs single-ECG model with age and sex
+0.007; 95% CI: 0.003-0.012
Paired area under the receiver-operating characteristic curve with ≥1 prior ECG
+0.014
Further findings
Atrial fibrillation (AF)-free survival, high-risk patients
| HR (95% CI) | ||
|---|---|---|
| High-risk patientsHigh-risk patients had lower AF-free survival | 8.8 (7.8–10.0) | |
| 0.10.31310Hazard ratio (log scale) |
ECG-only advantage without retraining on MIMIC-IV-ECG
- Advantage confined to patients with ≥1 prior ECG
- +0.014; 95% CI: 0.004-0.024
Matched advantage after external-domain adaptation
- Matched advantage
- +0.007 (95% CI: 0.002-0.012)