Arrhythmias & electrophysiologyCohort study
Delineation of conduction gaps of linear lesions during atrial fibrillation ablation using ultra-high-density mapping
- Retrospective study
- ultra-high-density mapping (RHYTHMIA)
Authors' conclusion
The entrances and exits of electrical conduction gaps were separated, especially in the roof region, indicating that epicardial conduction might contribute to gap formation.
Study context
- Population
- Patients with conduction gaps along pulmonary vein (PV) isolation or box ablation lesions during AF ablationmaps in 31 patients
- Participants
- 34 patients
- Exposure
- Gap length by lesion region
- Boxn = 21
- PVIn = 13
Main finding
As reported in the abstract
Gap length (entrance–exit distance)
Roof region (box) vs Bottom region (box): P = 0.022 · Right PV (PVI) vs Left PV (PVI): P = 0.201
Observational data: associations, not effects.
Further findings
events
| Outcome | Roof region (box) | Bottom region (box) | Right PV (PVI) | Left PV (PVI) |
|---|---|---|---|---|
| Gap locations | 9 | 12 | 9 | 4 |
Original publication
Delineation of conduction gaps of linear lesions during atrial fibrillation ablation using ultra-high-density mapping. Europace. Published 3 July 2023. doi:10.1093/europace/euad188
Summarised from the published abstract; every number is checked against it