Derivation and validation of an artificial intelligence-based plaque burden safety cut-off for long-term acute coronary syndrome from coronary computed tomography angiography

Eur Heart J Cardiovasc ImagingPublished Derivation and validation of an artificial intelligence-based plaque burden safety cut-off

Authors' conclusion

This study suggests that PAV up to 2.6% quantified by AI is associated with low-ACS risk in two independent patient cohorts. This cut-off may be helpful for clinical application of AI-guided CCTA analysis, which detects any plaque in up to 96-97% of patients.

Study context

Population
Patients undergoing coronary computed tomography angiography (CCTA) in the Turku CCTA registry (Finland) and the Amsterdam CCTA registry (the Netherlands)derivation and validation cohorts · 2,271 (Derivation cohort, Turku CCTA registry) · 568 (Validation cohort, Amsterdam CCTA registry)Events: derivation cohort 100/2271 (4.4%); validation cohort 27/568 (4.8%)
Predictors
Percent atheroma volume (PAV) quantified with artificial intelligence (AI)-guided quantitative computed tomography; threshold PAV ≥ 2.6%
Predicted outcome
Acute coronary syndrome (ACS)
Methodological detailsblinded quantification, external validation, registry-based
  • Blinded quantification
  • External validation
  • Registry-based

Model performance

As reported in the abstract

Acute coronary syndrome (ACS)
Test or modelValueSensitivityNPV
Derivation cohort100/2271 (4.4%) events90.0%99.0%
Validation cohort27/568 (4.8%) events92.6%99.0%

Value

Derivation cohort100/2271 (4.4%) events
Validation cohort27/568 (4.8%) events

Sensitivity

Derivation cohort90.0%
Validation cohort92.6%

NPV

Derivation cohort99.0%
Validation cohort99.0%

Further findings

Proportion of patients with PAV < 2.6 vs. PAV 0% (no plaque)

PAV < 2.6

PAV 0% (no plaque) Derivation cohort 4.3%

PAV 0% Validation cohort 2.6%

Adjusted acute coronary syndrome (ACS) rates

HR (95% CI)P value
PAV ≥ 2.6%Derivation cohort · adjusted4.65 (2.33–9.28)P < 0.001
PAV ≥ 2.6%Validation cohort · adjusted7.31 (1.62–33.08)P = 0.010
  • Proportion of patients with PAV < 2.6 vs. PAV 0% (no plaque): Derivation cohort P < 0.001
  • Proportion of patients with PAV < 2.6 vs. PAV 0% (no plaque): Validation cohort P < 0.001

Original publication

Derivation and validation of an artificial intelligence-based plaque burden safety cut-off for long-term acute coronary syndrome from coronary computed tomography angiography. Eur Heart J Cardiovasc Imaging. Published 17 April 2025. doi:10.1093/ehjci/jeaf121

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.