Derivation and validation of an artificial intelligence-based plaque burden safety cut-off for long-term acute coronary syndrome from coronary computed tomography angiography
Authors' conclusion
This study suggests that PAV up to 2.6% quantified by AI is associated with low-ACS risk in two independent patient cohorts. This cut-off may be helpful for clinical application of AI-guided CCTA analysis, which detects any plaque in up to 96-97% of patients.
Study context
- Population
- Patients undergoing coronary computed tomography angiography (CCTA) in the Turku CCTA registry (Finland) and the Amsterdam CCTA registry (the Netherlands)derivation and validation cohorts · 2,271 (Derivation cohort, Turku CCTA registry) · 568 (Validation cohort, Amsterdam CCTA registry)Events: derivation cohort 100/2271 (4.4%); validation cohort 27/568 (4.8%)
- Predictors
- Percent atheroma volume (PAV) quantified with artificial intelligence (AI)-guided quantitative computed tomography; threshold PAV ≥ 2.6%
- Predicted outcome
- Acute coronary syndrome (ACS)
Methodological detailsblinded quantification, external validation, registry-based
- Blinded quantification
- External validation
- Registry-based
Model performance
As reported in the abstract
Acute coronary syndrome (ACS)
| Test or model | Value | Sensitivity | NPV |
|---|---|---|---|
| Derivation cohort | 100/2271 (4.4%) events | 90.0% | 99.0% |
| Validation cohort | 27/568 (4.8%) events | 92.6% | 99.0% |
Value
Derivation cohort100/2271 (4.4%) events
Validation cohort27/568 (4.8%) events
Sensitivity
Derivation cohort90.0%
Validation cohort92.6%
NPV
Derivation cohort99.0%
Validation cohort99.0%
Key notes
- Safety cut-off pre-defined as ≥90% sensitivity for ACS
- Median follow-up 6.9 years (derivation) and 6.7 years (validation)
Further findings
Proportion of patients with PAV < 2.6 vs. PAV 0% (no plaque)
PAV < 2.6
PAV 0% (no plaque) Derivation cohort 4.3%
PAV 0% Validation cohort 2.6%
Adjusted acute coronary syndrome (ACS) rates
| HR (95% CI) | P value | ||
|---|---|---|---|
| PAV ≥ 2.6%Derivation cohort · adjusted | 4.65 (2.33–9.28) | P < 0.001 | |
| PAV ≥ 2.6%Validation cohort · adjusted | 7.31 (1.62–33.08) | P = 0.010 | |
| 0.050.21520Hazard ratio (log scale) |
- Proportion of patients with PAV < 2.6 vs. PAV 0% (no plaque): Derivation cohort P < 0.001
- Proportion of patients with PAV < 2.6 vs. PAV 0% (no plaque): Validation cohort P < 0.001
Original publication
Derivation and validation of an artificial intelligence-based plaque burden safety cut-off for long-term acute coronary syndrome from coronary computed tomography angiography. Eur Heart J Cardiovasc Imaging. Published 17 April 2025. doi:10. 1093/ ehjci/ jeaf121
Composed by AI from the published abstract and checked against it. How Briefs are made →