Development and validation of the Aortic valve Stenosis Guarded by Amplified Risk Determination (ASGARD) risk score for safe monitoring in asymptomatic non-severe aortic valve stenosis
Authors' conclusion
The ASGARD score could provide a personalized and safe surveillance alternative to routinely planned echocardiograms, so physicians can prioritize echocardiograms for high-risk patients.
Study context
- Population
- Asymptomatic patients with non-severe (mild-to-moderate) ASSEAS cohort plus 71 external
- Comparison
- ASGARD vs Vmax
- Outcome
- AS-related composite outcome:
- HF hospitalization
- Aortic valve replacement
- CV death
- Follow-up
- 2-year follow-up
Methodological detailsinternal and external validation, landmark analysis, Score comprises updated heart rate and age- and sex-adjusted NT-proBNP upon Vmax from the previous year
- Internal and external validation
- Landmark analysis
- Score comprises updated heart rate and age- and sex-adjusted NT-proBNP upon Vmax from the previous year
Performance
As reported in the abstract
Predictive accuracy of ASGARD score for AS-related composite outcome
| Test or model | AUC |
|---|---|
| External validation | 0.74 [95% CI, 0.62-0.86] |
External validation
AUC0.74 [95% CI, 0.62-0.86]
Key notes
- High predictive accuracy across all cohorts, similar to an updated Vmax measurement
- ASGARD score ≤ 50% associated with AS-related event rates ≤ 5% for a minimum of 15 months
Original publication
Development and validation of the Aortic valve Stenosis Guarded by Amplified Risk Determination (ASGARD) risk score for safe monitoring in asymptomatic non-severe aortic valve stenosis. Eur J Prev Cardiol. Published 28 February 2024. doi:10. 1093/ eurjpc/ zwae086
Composed by AI from the published abstract and checked against it. How Briefs are made →