Development and validation of the Aortic valve Stenosis Guarded by Amplified Risk Determination (ASGARD) risk score for safe monitoring in asymptomatic non-severe aortic valve stenosis

Eur J Prev CardiolPublished Risk score development and validation study

Authors' conclusion

The ASGARD score could provide a personalized and safe surveillance alternative to routinely planned echocardiograms, so physicians can prioritize echocardiograms for high-risk patients.

Study context

Population
Asymptomatic patients with non-severe (mild-to-moderate) ASSEAS cohort plus 71 external
Comparison
ASGARD vs Vmax
Outcome
AS-related composite outcome:
  • HF hospitalization
  • Aortic valve replacement
  • CV death
Follow-up
2-year follow-up
Methodological detailsinternal and external validation, landmark analysis, Score comprises updated heart rate and age- and sex-adjusted NT-proBNP upon Vmax from the previous year
  • Internal and external validation
  • Landmark analysis
  • Score comprises updated heart rate and age- and sex-adjusted NT-proBNP upon Vmax from the previous year

Performance

As reported in the abstract

Predictive accuracy of ASGARD score for AS-related composite outcome
Test or modelAUC
External validation0.74 [95% CI, 0.62-0.86]

External validation

AUC0.74 [95% CI, 0.62-0.86]

Original publication

Development and validation of the Aortic valve Stenosis Guarded by Amplified Risk Determination (ASGARD) risk score for safe monitoring in asymptomatic non-severe aortic valve stenosis. Eur J Prev Cardiol. Published 28 February 2024. doi:10.1093/eurjpc/zwae086