Cardio-oncology & otherCohort study

Device-Removal, Reinfection, and Mortality After Staphylococcus aureus Bacteremia in Patients With Cardiac Implantable Electronic Devices

JACC AdvPublished

  • nationwide register-based cohort study
  • sex and age-matched non-CIED controls with Staphylococcus aureus bacteremia (SAB)
  • landmark analysis at the time of hospital discharge

Authors' conclusion

The Danish CIED carriers had slightly higher 30-day all-cause mortality after SAB compared to matched controls. Only a minor selected proportion underwent device removal after SAB diagnosis and, after initial survival, these patients had lower 180-days reinfection rates and mortality compared to patients with retained devices.

Study context

Population
Patients with SAB after cardiac implantable electronic device (CIED) implantation in Denmark between 2000 and 2020patients with CIED and SAB, plus 9,080 matched controls · patients with CIED and SAB 1,816 · matched controls 9,080
Participants
1,816 patients
Exposure
patients with CIED vs controls
  • patients with CIEDn = 1,816
  • controlsn = 9,080reference

Main finding

All-cause mortality · 30 days

Adjusted hazard ratio

1.11

95% CI 1.02–1.22

P = 0.019

By group

patients with CIED vs controls
adjusted HR 1.11 (95% CI 1.02–1.22); P = 0.019

As reported in the abstract

Observational data: associations, not effects.

Further findings

Outcomepatients with CIEDcontrolsdevice removalretained CIEDs
Device removal · within 30 days15.8%Not reported in the abstractNot reported in the abstractNot reported in the abstract
Cumulative incidence of SAB reinfection and all-cause mortality (landmark analysis) · 180 days
reinfectionNot reported in the abstractNot reported in the abstract2.5%5.5%
mortalityNot reported in the abstractNot reported in the abstract7.8%31.2%

Cumulative incidence of SAB reinfection and all-cause mortality (landmark analysis) · 180 days

significantly lower in patients undergoing device removal compared to those with retained CIEDs

Baseline characteristics by removal status

Patients who underwent CIED removal were younger and had less comorbidity compared to those with retained CIEDs

Original publication

Device-Removal, Reinfection, and Mortality After Staphylococcus aureus Bacteremia in Patients With Cardiac Implantable Electronic Devices. JACC Adv. Published 20 January 2026. doi:10.1016/j.jacadv.2025.102480