Arrhythmias & electrophysiology

Diagnostic reliability of monitoring for premature atrial and ventricular complexes

EuropacePublished Diagnostic accuracy study

Authors' conclusion

While there is substantial daily variability across most PAC and PVC levels, findings of ≥10 000 PACs or PVCs are highly specific and do not need to be confirmed with longer recordings.

Study context

Population
US patients aged 17–103 years with 14-day mobile cardiac telemetry recordings without AF
Participants
8,245 patients
Comparison
Shorter ambulatory electrocardiogram (ECG) recordings vs 14-day averages
Outcome
Day-to-day variability of PAC and PVC frequency

Performance

As reported in the abstract

After 3 days, estimated daily premature atrial complex (PAC) frequency differed by ≥50% from the 14-day mean in this share of patients; for premature ventricular complex (PVCs) the corresponding duration was 7 days

25%

Days of monitoring needed to estimate PAC and PVC frequency within ±20% of the 14-day frequency in 80% of patients

10

Further findings

Sensitivity

OutcomePACsPVCs
Sensitivity for ≥10 000 PACs or PVCs/day after 7 days of monitoring88.8% (95% CI 83.6–92.9)86.9% (95% CI 80.9–91.5%)

Day-to-day variability: estimated daily frequency differing by ≥50% from 14-day mean in 25% of patients

PVCs: corresponding duration
7 days
PACs: after 3 days

Original publication

Diagnostic reliability of monitoring for premature atrial and ventricular complexes. Europace. Published 26 July 2024. doi:10.1093/europace/euae198

Summarised from the published abstract; every number is checked against it