Heart failure & cardiomyopathiesCohort study

Diurnal variation in left atrial pressure in ambulatory patients with chronic heart failure

Eur J Heart FailPublished

  • Prospective observational cohort study
  • implantable intracardiac left atrial pressure (LAP) sensor
  • longitudinal follow-up

Authors' conclusion

Using direct ambulatory intracardiac LAP monitoring, we observed consistent diurnal variation with higher evening pressures, largely unchanged by diuretic dose or dosing schedule, atrial fibrillation, or association with ADHF events.

Study context

Population
Ambulatory patients with chronic HF with an implantable intracardiac LAP sensor>15,500 measurement days
Participants
73 patients
Exposure
Evening vs morning LAP
Outcome
Diurnal variation in LAP (morning vs evening)
Follow-up
Average 25.5±18.6 months

Main finding

As reported in the abstract

LAP

P < 0.01

Observational data: associations, not effects.

Further findings

OutcomeValuesOR (95% CI)P value
Higher LAP and risk of ADHF events · independently associated1.40 (1.10–1.78)P < 0.01
OutcomeValuesEstimateP value
LAP in patients with vs without ADHF eventsADHF events median 14.3 (IQR 9.5–19.9) mmHg · No ADHF events median 10.4 (IQR 5.4–17.3) mmHgP < 0.01

Diurnal variation by diuretic dose, twice-daily dosing or AF

Neither higher diuretic dose, twice-daily dosing, nor AF modified the diurnal variation
P = 0.98, p=0.50

Diurnal variation by acute decompensated heart failure (ADHF) status

Diurnal variation present irrespective of ADHF status
P = 0.79

Original publication

Diurnal variation in left atrial pressure in ambulatory patients with chronic heart failure. Eur J Heart Fail. Published 31 August 2026. doi:10.1093/ejhf/xuag280

Summarised from the published abstract; every number is checked against it