Arrhythmias & electrophysiologyMechanistic study

Diverse QRS morphology reflecting variations in lead placement for left bundle branch area pacing

EuropacePublished

  • Mechanistic study

Authors' conclusion

Different QRS morphologies and axes were linked to the location of the non-selective LBBAP lead in the septum. Various lead deployments are feasible for LBBAP, allowing diversity in the conduction system capture in patients with atrioventricular block.

Study context

Population
Patients with atrioventricular block
Participants
50 vs 21
Comparison
Non-selective left bundle branch area pacing (LBBAP) vs LVSP; lead location in the septum
  • Non-selective LBBAPn = 50
  • LVSPn = 21reference
Outcome
Impact of septal lead location on QRS morphology during non-selective LBBAP

Main finding

As reported in the abstract

QRS morphology and lead location

qR-wave in V1 indicated inferior septum as primary lead location

93%

Further findings

Penetration depth of non-selective LBBAP lead, anterior vs inferior septum

Penetration depth of non-selective LBBAP lead, anterior vs inferior septum

Significantly shallower in the anterior septum

Original publication

Diverse QRS morphology reflecting variations in lead placement for left bundle branch area pacing. Europace. Published 25 September 2023. doi:10.1093/europace/euad241