Arrhythmias & electrophysiologyCohort study

Dual-chamber vs. single-chamber pacemaker in patients in sinus rhythm with an atrioventricular block: a nationwide cohort study

EuropacePublished

  • Retrospective cohort study
  • propensity-score matched
  • nationwide
  • national administrative database

Authors' conclusion

Implantation of a dual-chamber pacemaker is associated with a lower risk of mortality, heart failure, atrial fibrillation, and stroke during follow-up.

Study context

Population
Patients with primary pacemaker implantation for complete atrioventricular block (AVB) with underlying sinus rhythm, France, January 2013–December 2022matched cohort
Participants
19,219 vs 19,219
Exposure
Dual-chamber vs single-chamber pacemaker
  • Dual-chambern = 19,219
  • Single-chambern = 19,219reference
Outcome
All-cause mortality

Main finding

As reported in the abstract

Hazard ratio

0.807

P < 0.0001

By group

Dual-chamber

9.22%/year

Single-chamber

11.48%/year

Observational data: associations, not effects.

Further findings

OutcomeHRP value
CV mortality, HF, AF, ischaemic stroke — Dual-chamber vs Single-chamber · CV mortality0.766P < 0.0001
CV mortality, HF, AF, ischaemic stroke — Dual-chamber vs Single-chamber · HF0.908P < 0.0001
CV mortality, HF, AF, ischaemic stroke — Dual-chamber vs Single-chamber · AF0.778P < 0.0001
CV mortality, HF, AF, ischaemic stroke — Dual-chamber vs Single-chamber · ischaemic stroke0.873P = 0.008

Safety

OutcomeHRP value
Re-interventions and complications — Dual-chamber vs Single-chamber · upgrades (addition of atrial or LV lead), fewer0.210P < 0.0001
Re-interventions and complications — Dual-chamber vs Single-chamber · haematomas, more1.179P = 0.006
Re-interventions and complications — Dual-chamber vs Single-chamber · lead repositioning, more1.123P = 0.04

Original publication

Dual-chamber vs. single-chamber pacemaker in patients in sinus rhythm with an atrioventricular block: a nationwide cohort study. Europace. Published 13 September 2024. doi:10.1093/europace/euae238

Summarised from the published abstract; every number is checked against it