Valvular & structural heart diseaseCohort study

Early outcomes of redo-TAVI with the SAPIEN 3 platform: the prospective, multicentre ReTAVI registry

EuroInterventionPublished

  • prospective, international study
  • registry
  • consecutive patients
  • 59 international centres
  • imaging centrally analysed
  • major clinical events adjudicated by an independent committee

Authors' conclusion

Redo-TAVI with a balloon-expandable SAPIEN 3 THV platform is a safe and effective reintervention strategy across diverse failed THV types, when guided by the Heart Team, standardised procedural planning, and comprehensive imaging.

Study context

Population
Patients with a failed aortic transcatheter heart valve (THV) undergoing redo-TAVI with a balloon-expandable SAPIEN 3 THVenrolled
Participants
143 patients

Main finding

As reported in the abstract

Baseline characteristics

median age

84 years

female

40.6%

median Society of Thoracic Surgeons risk score

7.0%

Observational data: associations, not effects.

Further findings

Failing THV platform

balloon-expandable SAPIEN 3
30.1%
self-expanding CoreValve/Evolut
53.1%
ACURATE
14.0%

Failure mode

isolated regurgitation
48.6%
stenosis
35.2%
mixed pathology
16.2%

Replacement valve successfully implanted

successful implantation
95.1%

Mortality · 30 days

30-day mortality rate
3.5%

Mean gradient change

overall
Δ=−12.0 mmHg
stenotic failures
Δ=−29.0 mmHg

Safety

Stroke and pacemaker implantation · 30 days

stroke
0.7%
pacemaker implantation
6.3%

Coronary obstruction

coronary obstruction
1.4%

Original publication

Early outcomes of redo-TAVI with the SAPIEN 3 platform: the prospective, multicentre ReTAVI registry. EuroIntervention. Published 1 June 2026. doi:10.4244/eij-d-25-01268

Summarised from the published abstract; every number is checked against it