Heart failure & cardiomyopathies

Effectiveness of adding a defibrillator with cardiac resynchronization therapy in heart failure according to the modified Model for End-stage Liver Disease-Albumin score

EuropacePublished Cohort study

Authors' conclusion

Our findings suggest that CRT-D is associated with an excess risk of composite clinical endpoints in HF patients with higher MELD-Albumin score.

Study context

Population
HF patients with CRT with pacemaker (CRT-P) or CRT-D implantation, 2010–2022
Participants
752 patients
Exposure
CRT-D vs CRT-P, by MELD-Albumin score
  • CRT-Pn = 291reference
Outcome
Composite of:
  • All-cause mortality
  • Worsening HF
Follow-up
Median 880 days
Methodological detailsconsecutive patients, multivariable-adjusted Cox regression
  • Consecutive patients
  • Multivariable-adjusted Cox regression

Main finding

As reported in the abstract

Primary endpoint by MELD-Albumin score
Each group vs CRT-PHazard ratio (CI)P value
CRT-Dassociation of MELD-Albumin score with primary endpoint within CRT-D
1.16(1.09–1.24)
P < 0.001
CRT-Passociation of MELD-Albumin score with primary endpoint within CRT-P
1.03(0.95–1.12)
P = 0.49
CRT-DMELD-Albumin ≥ 12
1.99(1.10–3.58)
P = 0.02
CRT-DMELD-Albumin < 12
1.19(0.83–1.70)
P = 0.35
Patients reaching the primary endpoint
205
Optimal MELD-Albumin cut-off
12

Observational data: associations, not effects.

Original publication

Effectiveness of adding a defibrillator with cardiac resynchronization therapy in heart failure according to the modified Model for End-stage Liver Disease-Albumin score. Europace. Published 4 August 2023. doi:10.1093/europace/euad232

Summarised from the published abstract; every number is checked against it