Arrhythmias & electrophysiology

Electrogram-guided Bachmann bundle area pacing to correct interatrial block: Initial experience, safety, and feasibility

Heart RhythmPublished Prospective cohort study

Authors' conclusion

BBAP is feasible in a high percentage of patients and is associated with stable capture thresholds during follow-up.

Study context

Population
Patients with baseline interatrial block undergoing dual-chamber pacemaker or ICD implantation
Participants
36 patients
Outcome
Feasibility and safety of electrogram-guided BB pacing
Methodological detailssingle-centre
  • Single-centre

Main finding

As reported in the abstract

Permanent BBAP success

Bachmann bundle area pacing (BBAP)

88.9%

32 of 36

Observational data: associations, not effects.

Further findings

P-wave duration (baseline vs final paced, successful Bachmann bundle pacing (BBP))

Baseline P-wave duration
148.5 ± 16.1 ms
Final paced P-wave duration among patients with successful BBP
117.8 ± 19.6ms

Correction of interatrial block (IAB)

Patients

Correction of partial IAB
22 (91.7%)
Correction of complete IAB
6 (75.0%)

Bachmann bundle (BB) potentials recorded

BB potentials recorded in all study patients
83.3%

Transition from NS to S BB capture during threshold testing

Transition demonstrated
22 patients (87.5%)

Safety

OutcomeValues
Major complicationsBBAP Lead dislodgment within 24 hours 2 · Rise in pacing impedance at 3 weeks 1

Original publication

Electrogram-guided Bachmann bundle area pacing to correct interatrial block: Initial experience, safety, and feasibility. Heart Rhythm. Published 20 August 2024. doi:10.1016/j.hrthm.2024.08.024

Composed by AI from the published abstract and checked against it. How Briefs are made →