Arrhythmias & electrophysiology

Electrogram-guided pulsed field ablation for persistent atrial fibrillation: A prospective cohort study

Heart RhythmPublished prospective cohort study

Main finding · Freedom from AF/atrial tachycardia (AT) recurrence after a single procedure, off antiarrhythmic drugsResult — go to the resultHazard ratio .47 95% CI 0.25–0.87

Authors' conclusion

In this single-center, nonrandomized comparative cohort study, EGM-guided PFA demonstrated preliminary efficacy and safety in PerAF ablation, suggesting promising prospects as an innovative strategy for PerAF ablation. (ClinicalTrials, NCT06729866, EGM Guided PFA for PerAF).

Study context

Population
Patients with persistent atrial fibrillation (PerAF) undergoing pulsed field ablation (PFA)Electrogram (EGM) group 85 · PWI group 85
Participants
85 vs 85
Exposure
EGM-guided PFA vs anatomic pulmonary vein isolation plus PWI
  • EGM groupn = 85
  • PWI groupn = 85reference
Outcome
Freedom from AF/atrial tachycardia (AT) recurrence after a single procedure, off antiarrhythmic drugs
Follow-up
12 months
Methodological detailssingle-center, nonrandomized comparative cohort study
  • Single-center
  • Nonrandomized comparative cohort study

Main finding

As reported in the abstract

Freedom from AF/atrial tachycardia (AT) recurrence after a single procedure, off antiarrhythmic drugs

Hazard ratio

.47

95% CI 0.25–0.87

log-rank P = .017

Events by group

Observational data: associations, not effects.

Further findings

Intraprocedural AF termination · significantly higher in EGM group

P < 0.001

OutcomeHazard ratio (95% CI)P value
AF-/AT-free survival by procedural AF termination0.40 (0.21–0.77)log-rank P = .007
  • Atrial fibrillation (AF)-/AF/atrial tachycardia (AT)-free survival by procedural AF termination: procedural AF termination 84.1%
  • AF-/AT-free survival by procedural AF termination: non-AF termination 64.8%

Safety

OutcomeEGM groupPWI group
Primary safety end point (PFA-related adverse events)1.2%Not reported in the abstractPWI group: not reported in the abstract
Primary safety end point (PFA-related adverse events) — hemolysis in 1 patient in the EGM group
1.2%

Primary safety end point (PFA-related adverse events)

No other PFA-related adverse event was observed

Original publication

Electrogram-guided pulsed field ablation for persistent atrial fibrillation: A prospective cohort study. Heart Rhythm. Published 10 March 2026. doi:10.1016/j.hrthm.2026.03.1878

Summarised from the published abstract; every number is checked against it

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.