Arrhythmias & electrophysiologyResearch article

Electrographic flow mapping of persistent atrial fibrillation: intra- and inter-procedure reproducibility in the absence of ‘ground truth’

EuropacePublished

  • Reproducibility study

Authors' conclusion

Electrographic flow mapping generates reproducible intra- and inter-procedural maps, providing rationale for randomized clinical trials targeting these putative AF sources.

Study context

Population
Persistent atrial fibrillation (AF) patients after pulmonary vein isolation (PVI), electrographic flow (EGF) mapping with 64-electrode basket catheter12 returned for 3-month remapping
Participants
23 patients
Outcome
Intra- (3 min) and inter- (>3 months) procedure EGF map reproducibility

Main finding

As reported in the abstract

Intra-procedure reproducibility (224 map triplets: 111 right atrium, 113 left atrium) · 3 min

Exact match of leading sources on all 3 maps

97 triplets (43%)

Leading source within 1 electrode space on 2 of 3 maps

95 triplets (42%)

Chaotic leading source pattern

32 triplets (14%)

Average deviation in source prevalence over 60 s

6.4%

Further findings

Inter-procedure reproducibility (spatiotemporal stability of EGF mapping) · >3 months

Stable sources, of sources mapped in 12 patients with (re)inducible AF
16 of 18 (89%)
  • 1 patient non-inducible at remapping

Original publication

Electrographic flow mapping of persistent atrial fibrillation: intra- and inter-procedure reproducibility in the absence of ‘ground truth’. Europace. Published 10 November 2023. doi:10.1093/europace/euad308

Summarised from the published abstract; every number is checked against it