Arrhythmias & electrophysiologyCohort study

Evaluation of posterior mitral isthmus ablation in the absence of a vein of Marshall

EuropacePublished

  • Matched cohort study
  • matched control group

Authors' conclusion

The absence of a VoM is associated with a very high rate of procedural block during posterior MI ablation.

Study context

Population
Patients undergoing posterior mitral isthmus radiofrequency (RF) ablation without an angiographic vein of Marshall
Exposure
Posterior mitral isthmus ablation without Vein of Marshall (VoM) vs matched controls
  • No VoMn = 37
Outcome
Procedural mitral isthmus block

Main finding

As reported in the abstract

Mitral isthmus block

P < 0.01

Observational data: associations, not effects.

Further findings

RF tags

P = 0.8

RF time

P = 0.08

Ablation approach for block (No VoM)
5/37 (14%) · Endocardial ablation only · Combined endocardial and coronary sinus ablation 32/37 (86%)

Original publication

Evaluation of posterior mitral isthmus ablation in the absence of a vein of Marshall. Europace. Published 1 October 2024. doi:10.1093/europace/euae255

Summarised from the published abstract; every number is checked against it