Extended Rhythm Monitoring to Assess for Ventricular Arrhythmias After Transcatheter Pulmonary Valve Replacement With the Harmony Valve
Authors' conclusion
NSVT and ventricular ectopy were common early after TPVR but were infrequent in most cases and diminished rapidly after discharge.
Study context
- Population
- Patients undergoing Harmony transcatheter pulmonary valve replacement (TPVR)
- Participants
- 54 patients
- Exposure
- Tetralogy of Fallot vs Valvar pulmonary stenosis vs Pulmonary atresia with intact ventricular septum
- Tetralogy of Fallotn = 39
- Valvar pulmonary stenosisn = 10
- Pulmonary atresia with intact ventricular septumn = 5
- Outcome
- Ventricular arrhythmias (NSVT) on postimplant telemetry and follow-up extended rhythm monitoring
- Follow-up
- Implant through mid-term
Main finding
As reported in the abstract
NSVT
- Nonsustained ventricular tachycardia (NSVT) on postimplant telemetry (most <5 episodes; 1 torsade de pointes)
- 27 patients (50%)
- NSVT on discharge extended rhythm monitoring (ERM) (most <5 episodes)
- 37%
- NSVT beyond 5 days post-discharge
- 13%
- Single NSVT episode on follow-up ERM
- 14%
- 5 NSVT episodes on follow-up ERM
- 1
Observational data: associations, not effects.
Further findings
Factors associated with more frequent NSVT on telemetry
- Pre-TPVR NSVT or rhythm medications, diagnosis other than tetralogy, and substantial device contact with myocardium associated with more frequent NSVT
New antiarrhythmic medication
- Started on new antiarrhythmic medication
- 10 patients (19%)
- Discontinued during follow-up
- 8 of 10
Death or sustained VT during follow-up
- Deaths
- 0
- Sustained VT
- 0
Original publication
Extended Rhythm Monitoring to Assess for Ventricular Arrhythmias After Transcatheter Pulmonary Valve Replacement With the Harmony Valve. Circ Cardiovasc Interv. Published 27 December 2024. doi:10. 1161/ circinterventions. 124. 014381
Composed by AI from the published abstract and checked against it. How Briefs are made →