Heart failure & cardiomyopathiesDiagnostic or prognostic study

External validation of an explainable electrocardiogram-only deep learning algorithm for the prediction of response after cardiac resynchronization therapy

Heart RhythmPublished

  • external validation study

Authors' conclusion

In this external validation study, an explainable ECG-only algorithm for the prediction of nonresponse after CRT device implantation generalized well to a lower-risk population from a different hospital. Adding indices of mechanical dyssynchrony and right ventricular function might be of additional value when evaluating volumetric response.

Study context

Population
Patients with cardiac resynchronization therapy (CRT) from the University of Virginiaexternal validation cohort, model developed in 1306 patients with CRT from the Netherlands · Development cohort (Netherlands) 1,306 · External validation cohort (University of Virginia) 161
Participants
161 patients
Comparison
The original model vs American Heart Association criteria for left bundle branch block for the prediction of nonresponse

Further findings

OutcomeFactorECG algorithmAmerican Heart Association criteria for left bundle branch block
Prediction of volumetric nonresponse (C-statistic)
C-statisticNot reported in the abstract0.51 (95% CI 0.41-0.60)
  • Prediction of volumetric nonresponse (C-statistic): Original model C-statistic 0.67 (95% confidence interval [CI] 0.59-0.76)
  • Prediction of nonresponse: refitted FactorECG-based model vs model also integrating indices of mechanical dyssynchrony: Refitted FactorECG-based model C-statistic 0.74 [95% CI 0.66-0.82]
  • Prediction of nonresponse: refitted FactorECG-based model vs model also integrating indices of mechanical dyssynchrony: Model also integrating indices of mechanical dyssynchrony C-statistic 0.70 [95% CI 0.62-0.77]

Prediction of volumetric nonresponse (C-statistic)

The original model significantly outperformed American Heart Association criteria for left bundle branch block

Prediction of nonresponse: refitted FactorECG-based model vs model also integrating indices of mechanical dyssynchrony

Performed similarly

Prediction of response: combination of both models

C-statistic
0.79 [95% CI 0.71-0.85]

Original publication

External validation of an explainable electrocardiogram-only deep learning algorithm for the prediction of response after cardiac resynchronization therapy. Heart Rhythm. Published 10 January 2026. doi:10.1016/j.hrthm.2026.01.014

Summarised from the published abstract; every number is checked against it