Arrhythmias & electrophysiologyCohort study

Extraction of lumenless pacing leads from the His bundle and left bundle branch area: outcomes of the high-volume centre

EuropacePublished

  • Single-centre registry study
  • EXTRACT Registry
  • Department of Electrocardiology in Katowice, Poland

Authors' conclusion

The CSP lead extraction is safe and feasible with a low complication rate and high rate of CSP lead reimplantation.

Study context

Population
Patients with indication for removal of lumenless conduction system pacing (CSP) leads from the His bundle or left bundle branch area
Participants
47 patients
Outcome
Procedural outcomes and safety of CSP lead removal

Main finding

As reported in the abstract

Leads successfully removed
43 (91.5%)
Removed with traction only
41 (87.2%)
Leads removed from left bundle branch (LBB) area
7 (14.9%)
Leads removed from His bundle (HB)
36
Extracted leads with dwelling time >1 year
28
Oldest extracted lead implant duration
89 months

Observational data: associations, not effects.

Further findings

New CSP lead reimplantation

New CSP leads implanted
27 out of 31 attempts (87.1%)
HB pacing leads
9 (33.3%)
LBB area pacing leads
18 (66.7%)

Safety

Transient complete atrioventricular block during procedure

Patients with transient complete AV block
2

Original publication

Extraction of lumenless pacing leads from the His bundle and left bundle branch area: outcomes of the high-volume centre. Europace. Published 13 August 2024. doi:10.1093/europace/euae213

Summarised from the published abstract; every number is checked against it