Haemodynamic Effects of Intra-Aortic Balloon Pumps Stratified by Baseline Pulmonary Artery Pulsatility Index

ESC Heart FailPublished Retrospective cohort study

Authors' conclusion

IABP devices in those with HF-CS and low or abnormal PAPi may provide modest short-term haemodynamic benefits without significant improvement in CI, along with greater need for adjustment in medical therapeutics to achieve haemodynamic optimization.

Study context

Population
Patients with HF-related cardiogenic shock (HF-CS) undergoing intra-aortic balloon pump (IABP) placement, 2020–2022
Participants
67 patients
Exposure
IABP support stratified by baseline pulmonary artery pulsatility index (PAPi) <2.0 vs ≥2.0
  • PAPi <2.0n = 38
  • PAPi ≥2.0n = 29reference
Outcome
Haemodynamic changes on pulmonary artery catheter monitoring
Follow-up
72 h following IABP placement
Methodological detailssingle-centre, consecutive patients
  • Single-centre
  • Consecutive patients

Main finding

As reported in the abstract

Haemodynamic changes after IABP (baseline to 72 h) · 72 h
GroupCentral venous pressure (CVP)Mean pulmonary artery pressure (mPAP)PAPiCardiac indexmPA
PAPi <2.020 to 12 mmHg, P < 0.00137.5 to 28.5 mmHg, P = 0.0011 to 1.6, P = 0.0012 to 2.1 L/min/m², P = 0.31
PAPi ≥2.010 to 8 mmHg, P = 0.472.6 to 2.8, P = 0.921.9 to 2.5 L/min/m², P = 0.00437 to 29 mmHg, P = 0.03

Central venous pressure (CVP)

PAPi <2.020 to 12 mmHg, P < 0.001
PAPi ≥2.010 to 8 mmHg, P = 0.47

Mean pulmonary artery pressure (mPAP)

PAPi <2.037.5 to 28.5 mmHg, P = 0.001
PAPi ≥2.0Not reported in the abstract

PAPi

PAPi <2.01 to 1.6, P = 0.001
PAPi ≥2.02.6 to 2.8, P = 0.92

Cardiac index

PAPi <2.02 to 2.1 L/min/m², P = 0.31
PAPi ≥2.01.9 to 2.5 L/min/m², P = 0.004

mPA

PAPi <2.0Not reported in the abstract
PAPi ≥2.037 to 29 mmHg, P = 0.03

Observational data: associations, not effects.

Further findings

Increase in diuretic requirement · 72 h

P = 0.01

Addition of inotropes/vasopressors · 72 h

P = 0.07

LV assist device

P = 0.02

VA-ECMO escalation, 30-day mortality, renal replacement therapy, heart transplantation

No overall significant differences

Original publication

Haemodynamic Effects of Intra-Aortic Balloon Pumps Stratified by Baseline Pulmonary Artery Pulsatility Index. ESC Heart Fail. Published 18 September 2024. doi:10.1002/ehf2.15083

Summarised from the published abstract; every number is checked against it