Heart failure & cardiomyopathiesCohort study

Hemodynamic changes in response to GLP-1 treatment in ICD and CRT patients: insights from HeartLogic sensor data

Eur J Heart FailPublished

  • Retrospective cohort study
  • matched 1:5 by sex and age
  • nationwide
  • prespecified subgroup analyses

Authors' conclusion

GLP-1RA initiation was associated with measurable changes in device-derived physiology.

Study context

Population
Danish patients with implantable cardiac devices (ICD and CRT)matched cohort
Participants
666 patients
Exposure
GLP-1RA initiation vs no GLP-1RA
  • GLP-1RAn = 111
  • Controlsn = 555reference
Outcome
Changes in heart rate and thoracic impedance (device sensor data)
Follow-up
30 days before to 30 days after initiation

Main finding

As reported in the abstract

GLP-1RA vs ControlsAdjusted difference, bpm (95% CI)P value
night heart rate
2.12(1.38–2.87)
P < 0.01
daily heart rate
1.46(0.65–2.06)
P < 0.01
GLP-1RA vs ControlsAdjusted difference, Ω (95% CI)P value
thoracic impedance
0.66(0.17–1.15)
P < 0.01

Observational data: associations, not effects.

Further findings

S1 amplitude · 30 days after initiation

S1 amplitude decreased after GLP-1RA initiation (−0.09 mG; 95% CI, −0.14 to −0.04)
P < 0.01

Heart rate by semaglutide dose level

Stepwise HR increase across semaglutide dose levels; average increase per dose escalation
2.5 bpm

Heart failure and reduced ejection fraction (HFrEF) subgroup (GLP-1RA n = 80)

Findings directionally consistent in HFrEF, no evidence of effect modification
  • prespecified subgroup analysis

Original publication

Hemodynamic changes in response to GLP-1 treatment in ICD and CRT patients: insights from HeartLogic sensor data. Eur J Heart Fail. Published 16 April 2026. doi:10.1093/ejhf/xuag114

Summarised from the published abstract; every number is checked against it