Cardio-oncology & other

Hemodynamic, ventilatory and gas exchange responses to exercise using a cycle ergometer and the incremental shuttle walk test in pregnant women

Am Heart JPublished Prospective observational study

Authors' conclusion

CPET and ISWT are safe and feasible in women in second trimester including those at or beyond 24 weeks gestation.

Study context

Population
Healthy pregnant women in second trimester (14 to 27 gestational weeks)28 also completed incremental shuttle walk test (ISWT)
Participants
90 women
Outcome
Reference intervals for V̇O2 at rest, anaerobic threshold (AT) and submaximal exercise by CPET, and for ISWT distance
Methodological detailssingle-centre, tertiary referral hospital, Mean ± SD age 32 ± 3.2 years; Body mass index (BMI) 25 ± 2.7 kg/m²; median (IQR) gestation 23 (22-24) weeks
  • Single-centre
  • Tertiary referral hospital
  • Mean ± SD age 32 ± 3.2 years; BMI 25 ± 2.7 kg/m²; median (IQR) gestation 23 (22-24) weeks

Main finding

As reported in the abstract

Reference intervals in second trimester
V̇O2 at rest (cardiopulmonary exercise testing (CPET)), mL/kg/min
2.9 to 5.3
V̇O2 at anaerobic threshold (AT) (CPET), mL/kg/min
8.1 to 20.7
Submaximal V̇O2 (CPET), mL/kg/min
14.1 to 30.5
ISWT distance, meters
218 to 1058
Equation predicting submaximal V̇O2 from ISWT distance
submaximal V̇O2 (mL/kg/min) = 0.012*distance walked in ISWT (m) + 14.7
Pearson r, ISWT distance vs submaximal V̇O2
0.5426 95%CI 0.2126-0.7615, P = .0029

Observational data: associations, not effects.

Further findings

Prediction of submaximal V̇O2 from ISWT distance

Submaximal V̇O2 (mL/kg/min) = 0.012*ISWT distance (m) + 14.7; 95% CI slope 0.005-0.070
Pearson r = 0.5426 (95%CI 0.2126-0.7615), P = .0029

Hemoglobin (Hb) vs V̇O2 at AT

Positive correlation: AT V̇O2 (mL/kg/min) = 0.08*Hb (g/L) + 4.9; 95% CI slope 0.0791-0.143
Pearson r = 0.2538 (95%CI 0.049-0.438), P = .016

Ferritin vs submaximal V̇O2

No linear association
Pearson r = 0.431, P = .697

Safety

No maternal or fetal complications

Parts of this Brief are withheld: the automatic checks could not confirm them against the abstract.

Original publication

Hemodynamic, ventilatory and gas exchange responses to exercise using a cycle ergometer and the incremental shuttle walk test in pregnant women. Am Heart J. Published 15 March 2024. doi:10.1016/j.ahj.2024.03.007

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.