Arrhythmias & electrophysiologyCohort study

High-frequency areas as an electrophysiological clue for accessory pathway ablation: Characterizing spatial dissociation with peak frequency mapping

Heart RhythmPublished

  • multicenter retrospective study

Authors' conclusion

High-frequency areas on OTNF maps are consistently located adjacent to, but spatially distinct from, successful AP ablation sites. This quantifiable spatial dissociation represents a novel electrophysiological target that may improve the precision and efficiency of AP CA.

Study context

Population
Patients undergoing successful catheter ablation (CA) for atrioventricular reentrant tachycardia caused by accessory pathways (APs), with omnipolar technology near field (OTNF) mapping datapatients undergoing successful CA for atrioventricular reentrant tachycardia
Participants
33 patients
Exposure
Peak frequency (PF) at the successful ablation site vs the highest PF in the immediate vicinity

Main finding

As reported in the abstract

Peak frequency (PF)

P < 0.01

Observational data: associations, not effects.

Further findings

Spatial distance between highest PF site and successful ablation site

median distance
4 mm (interquartile range 0-6 mm)

Directional displacement of highest-frequency site, viewed from the annulus

cases

colocated with the successful site
21 (64%)
shifted counterclockwise
9 (27%)
shifted clockwise
3 (9%)

Original publication

High-frequency areas as an electrophysiological clue for accessory pathway ablation: Characterizing spatial dissociation with peak frequency mapping. Heart Rhythm. Published 6 February 2026. doi:10.1016/j.hrthm.2026.01.048

Summarised from the published abstract; every number is checked against it