Arrhythmias & electrophysiologyMechanistic study

Identifying extra pulmonary vein targets for persistent atrial fibrillation ablation: bridging advanced and conventional mapping techniques

EuropacePublished

  • Mechanistic study

Charge density mapping (CDM) and electroanatomic voltage mapping during atrial fibrillation (AF) and sinus rhythm with multiple pacing protocols; comparison via a left atrium statistical shape model

Authors' conclusion

Mapping techniques during paced rhythms do not reliably correspond with regions of CDM-identified propagation patterns in persistent AF. However, these propagation patterns are consistently observed in two specific anatomical regions, suggesting a predisposition to abnormal electrophysiological properties.

Study context

Population
Patients undergoing de novo ablation of persistent AF
Participants
22 patients
Comparison
CDM-identified propagation patterns vs low-voltage areas (LVAs) and slow conduction velocity (CV) regions on contact mapping
Outcome
Correspondence of left atrial regions containing CDM-identified pivoting and rotational propagation patterns during AF with conventional contact mapping (LVAs, slow CV)

Main finding

As reported in the abstract

CV mapping during AF correlated with pivoting-pattern regions (ρ)

−0.63, P < 0.0001

CV mapping during AF correlated with rotational-pattern regions (ρ)

−0.54, P < 0.0001

Original publication

Identifying extra pulmonary vein targets for persistent atrial fibrillation ablation: bridging advanced and conventional mapping techniques. Europace. Published 12 March 2025. doi:10.1093/europace/euaf048

Summarised from the published abstract; every number is checked against it