Coronary disease & ACS

Impact of Absolute Myocardial Blood Flow Quantification on the Diagnostic Performance of PET-Based Perfusion Scans Using 82 Rubidium

Circ Cardiovasc ImagingPublished Diagnostic accuracy study

Authors' conclusion

The inclusion of quantitative measurements to a RbPET read increases in the identification of obstructive CAD.

Study context

Population
Patients undergoing RbPET and invasive coronary angiography with FFR for suspected obstructive coronary artery disease (CAD)170 (42.5%) obstructive CAD
Participants
400 patients
Comparison
RbPET reading algorithms: SSS alone vs added quantitative myocardial blood flow (MBF) and MBF reserve
Outcome
Diagnostic accuracy for hemodynamically obstructive CAD (>90% diameter stenosis or FFR ≤0.80)
Methodological detailsprospective
  • Prospective

Performance

As reported in the abstract

Hemodynamically obstructive CAD
Test or modelSensitivitySpecificity
SSS57%93%
Hyperemic MBF61%85%
SSS + MBF + MBF reserve77%74%

Sensitivity

SSS57%
Hyperemic MBF61%
SSS + MBF + MBF reserve77%

Specificity

SSS93%
Hyperemic MBF85%
SSS + MBF + MBF reserve74%
  • Hyperemic MBF vs SSS: P = 0.57
  • Hyperemic MBF vs SSS: P = 0.008
  • SSS + MBF + MBF reserve vs SSS: P < 0.001 — 0.78 versus 0.85
  • SSS + MBF + MBF reserve vs SSS: P < 0.001 — P<0.001 for both comparisons

Further findings

Anatomically severe CAD (>70% diameter stenosis by QCA), sensitivity analysis

All measures independently yielded discrimination ≥0.90; added quantification increased sensitivity and lowered specificity

Original publication

Impact of Absolute Myocardial Blood Flow Quantification on the Diagnostic Performance of PET-Based Perfusion Scans Using 82 Rubidium. Circ Cardiovasc Imaging. Published 16 January 2024. doi:10.1161/circimaging.123.016138

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.