Arrhythmias & electrophysiologyCohort study

Impact of Insertable Cardiac Monitor-Detected Atrial Fibrillation on Future Ischemic Events Following Cryptogenic Stroke

JACC AdvPublished

  • retrospective analysis
  • consecutive patients
  • single stroke center

Authors' conclusion

Despite the high rate of detection of AF following CS by ICMs, most strokes occurring in this population may not be due to AF. Further randomized trials are needed to verify these observations and clarify the benefit of routine ICM implantation for secondary CS prevention.

Study context

Population
Patients admitted to a stroke center with no history of atrial fibrillation (AF) who received an ICM for cryptogenic stroke (CS) or transient ischemic attackmedian follow-up 990 days, AF detected in 235
Participants
840 patients
Exposure
stroke recurrence between CS patients with and without ICM-detected AF
  • AFn = 235

Main finding

Recurrent stroke · median follow-up 990 days

Adjusted hazard ratio

2.73

95% CI 1.33–5.59

AF vs No AF
adjusted HR 2.73 (95% CI 1.33–5.59)

As reported in the abstract

Patients with recurrent strokes
112
Recurrent strokes in patients without AF ever being detected
70.5%
Patients with AF started on anticoagulation
97.9%

Observational data: associations, not effects.

Further findings

Other predictors of recurrent stroke (multivariable)

CHA2DS2-VASc score ≥4 associated with increased risk
Male sex associated with increased risk

Recurrent stroke with AF detected, CHA2DS2-VASc score <4 and age of <65 years (exploratory subgroup)

Subgroup n
107
Patients with a recurrent stroke who had AF detected
1 patient (<1%)
  • exploratory subgroup analysis

Original publication

Impact of Insertable Cardiac Monitor-Detected Atrial Fibrillation on Future Ischemic Events Following Cryptogenic Stroke. JACC Adv. Published 20 January 2026. doi:10.1016/j.jacadv.2025.102536

Summarised from the published abstract; every number is checked against it