Arrhythmias & electrophysiologyCohort study

Impact of timing of treatment for cardiac implantable electronic device infections on healthcare utilization and expenditures

EuropacePublished

  • Retrospective cohort study
  • multivariable adjustment

Authors' conclusion

Extraction was associated with lower hospitalization and lower healthcare expenditures in the year following CIED infection management period. Early extraction was associated with optimal healthcare utilization and expenditures.

Study context

Population
Medicare fee-for-service patients with a de novo cardiovascular implantable electronic device (CIED) implant and CIED infection >12 months after implant, 2006–2019
Participants
9,594 patients
Exposure
Timing of CIED extraction vs no extraction within 30 days
  • No extraction within 30 daysn = 7,819reference
  • Extraction <7 daysn = 1,277
  • Extraction 7–30 daysn = 498
Outcome
Healthcare utilization (all-cause hospitalization) and expenditures

Main finding

All-cause hospitalization in follow-up

Adjusted hazard ratio

0.79

95% CI 0.72–0.85

P < 0.001

Extraction <7 days vs No extraction within 30 days
adjusted HR 0.79 (95% CI 0.72–0.85); P < 0.001

As reported in the abstract

Observational data: associations, not effects.

Further findings

OutcomeNo extraction within 30 daysExtraction <7 daysExtraction 7–30 days
Healthcare expenditures · year following CIED infectionmedian $63 425 (IQR $22,853, $120 273)median $36 824 (IQR $12,748, $77 772)Not reported in the abstract

Original publication

Impact of timing of treatment for cardiac implantable electronic device infections on healthcare utilization and expenditures. Europace. Published 29 August 2025. doi:10.1093/europace/euaf146

Summarised from the published abstract; every number is checked against it