Heart failure & cardiomyopathiesCohort study

Implementation of lead V8 as a simple non-invasive tool to improve patient selection in cardiac resynchronization therapy (CRT) and guide left ventricular (LV) lead placement

EuropacePublished

  • Prospective observational study
  • consecutive patients

Authors' conclusion

NDAT in lead V8 is a non-invasive marker of delayed activation in the posterolateral LV, outperforming V6 in identifying late activation. When combined with LV-paced QRS morphology, V8 facilitates accurate lead localization without additional tools.

Study context

Population
Patients with wide QRS (non-RBBB) undergoing BiV-CRT implantation or generator change
Participants
43 patients
Exposure
Negative derivative activation time (NDAT) in ECG lead V8 vs QLV interval
Outcome
Correlation of NDAT in lead V8 with the QLV interval

Main finding

As reported in the abstract

Correlation of NDAT with QLV
Grouprmean difference vs QLV
V80.8951 ± 11 ms
V60.59221 ± 24 ms

Observational data: associations, not effects.

Further findings

V8 morphology during LV-only pacing

QS morphology in V8 consistently indicated posterolateral LV lead placement
More anterior/apical lead positions showed larger QLV–NDAT V8 differences and non-QS morphologies, indicating suboptimal positioning

Original publication

Implementation of lead V8 as a simple non-invasive tool to improve patient selection in CRT and guide LV lead placement. Europace. Published 29 August 2025. doi:10.1093/europace/euaf194

Summarised from the published abstract; every number is checked against it