Arrhythmias & electrophysiologyCohort study

Incidence of laboratory-defined severe intravascular haemolysis across commercially available pulsed field ablation technologies for atrial fibrillation

EuropacePublished

  • Prospective observational study
  • consecutive patients

Authors' conclusion

Although over 17% of the cohort met the haematologic definition for significant IH, the absence of clinically significant renal impairment suggests that this threshold may not accurately reflect clinically meaningful haemolysis following PFA.

Study context

Population
Consecutive patients undergoing pulsed field ablation (PFA) for atrial fibrillation (AF), Sept 2024–May 2025
Participants
245 patients
Exposure
Pentaspline vs circular array vs lattice tip PFA catheters
  • Pentaspline (PS)n = 108
  • Circular array (CA)n = 75
  • Lattice tip (LT)n = 62
Outcome
Significant intravascular haemolysis (post-procedure free plasma haemoglobin > 100 mg/dL)

Main finding

As reported in the abstract

Incidence of significant intravascular haemolysis

P = 0.002

Observational data: associations, not effects.

Further findings

Independent predictors of intravascular haemolysis

Use of PS catheter, only independent predictor (OR)
3.42
No demographic or clinical parameters associated with higher risk
  • P = 0.001

Number of PF lesions (PS only)

Increased risk within PS group only (OR)
1.03
  • P = 0.049

Routine post-ablation laboratories

Poor sensitivity/specificity to define severe haemolysis

Original publication

Incidence of laboratory-defined severe intravascular haemolysis across commercially available pulsed field ablation technologies for atrial fibrillation. Europace. Published 22 August 2025. doi:10.1093/europace/euaf185

Summarised from the published abstract; every number is checked against it